Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- Soil profile moisture meter can measure soil profile moisture, temperature, and electrical conductivity
- Water quality testing manufacturer Fengtu: Offering online water quality analyzers, laboratory instruments and testing solutions
- Locust online monitoring station utilizes light-attracting and sex-attracting technologies to control locusts
- Buoy-based water quality monitoring brands Fengtu
- Integrated wireless meteorological and soil moisture monitoring station Provides an Integrated Soil Moisture, Temperature, and Conductivity Monitoring Solution
- Buoy-based online water quality monitoring equipment Real-time Monitoring of Multiple Water Quality Parameters
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Surface Water Quality Monitoring
Model:FT-DBS05
Brand:fengtu
Related products
Product details
1. Surface Water Quality Monitoring Product Introduction
Surface Water Quality Monitoring can be freely combined with a variety of water quality intelligent electrodes, widely used for surface water, river monitoring, lake monitoring.DBS05 Online Surface Water Quality Monitoring is an instrument that can monitor water temperature, pH, dissolved oxygen, turbidity, and conductivity online. It integrates the corresponding sensors and measurement module communication storage, and can quickly and accurately record key parameters in the water body. At the same time, the instrument supports the expansion of water quality multi-parameter sensors, including but not limited to pH, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data, alarm history records, and support historical data export.xlsx. The RS485 interface supports the MODBUS-RTU communication protocol to facilitate users to communicate freely with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2. Application fields of Surface Water Quality Monitoring
Online Surface Water Quality Monitoring is widely used in the monitoring and control of various water bodies, including but not limited to the following areas:
1. Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
2. Groundwater monitoring: used to monitor groundwater parameters such as pH value, conductivity, temperature, etc., so as to detect and solve water quality problems in time.
3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.
4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to timely detect and control marine pollution.
5. Sewage treatment: used to monitor sewage water quality parameters, such as pH, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.
6. Industrial production: used to monitor water quality in industrial production processes, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in time and ensure product quality.
7. Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.
3. Technical Features of Surface Water Quality Monitoring
1. High reliability: suitable for long-term work in the field environment, stable measurement and strong anti-interference ability.
2. Flexible and portable: Each probe can be freely combined, replaced independently, and plug and play.
3. Scalability: Various sensors can be freely combined.
4. Multiple applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water, and urban pipe network water.
5. Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6. Compact structure: can be installed in small places.
7. Communication connection: RS485 expansion interface, master/slave interface isolation and independent communication.
4. Surface Water Quality Monitoring Technical Parameters
| Display Output | 4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight |
| power supply | DC power supply: DC12V |
| Power consumption | The power consumption of the instrument is about 12V/1W |
| Sound Output | buzzer |
| Communication Protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support |
| Main Materials | ABS+PC material |
| Storage temperature | -20 to 70°C |
| Operating temperature | -10 to 50°C |
| Protection level | IP65 |
| size | 175mm*140mm*49mm(length×width×height) |
| weight | About 0.5KG |
5. Surface Water Quality Monitoring Sensor Configuration (optional)
| Serial number | name | Measuring range | principle | Measurement accuracy | Configuration | Remark |
| 1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ✔ | |
| 2 | pH | 0~14 (ph) | Electrochemistry (Salt Bridge) | ± 0.1PH | ✔ | |
| 3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ± 6mv | ||
| 4 | Conductivity | 0~5000uS/cm | Contact electrode method | ± 1.5% | ✔ | |
| 5 | Turbidity | 0~40NTU (low turbidity) | Scattered light method | ± 1% | Optional | |
| 0~1000NTU (medium turbidity) | Scattered light method | ± 1% | ||||
| 0~3000NTU (high turbidity) | Scattered light method | ± 1% | ✔ | |||
| 6 | Dissolved oxygen | 0~20mg/L | Fluorescence lifetime method | ± 2% | ✔ | |
| 7 | Ammonia nitrogen | 0-1000.00mg/L (default) 0-100.00mg/l/ (customizable) | Ion Selective Electrode Method | 10% of reading, ±0.5℃ | ||
| 8 | Suspended Matter | 0~2000mg/L | Scattered light method | ±5% (depending on sludge homogeneity) | ||
| 9 | Residual chlorine | 0~5.00 mg/L | Ion Selective Electrode Method | ±5% of reading | ||
| 10 | Chloride ion | 0-3500.0mg/L | Ion Selective Electrode Method | ±5% | ||
| 11 | Total hardness | 0~1000.0mg/L | Ion Selective Electrode Method | ±10% of reading | ||
| 12 | cod | 0~500mg/L | UV254 absorption method | ±5% | COD and chlorophyll are equipped with automatic cleaners to prevent biological attachment and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W | |
| 13 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
This paper addresses:https://www.fengtusz.com/On-line-Water-Quality-Analysis/Surface-Water-Quality-Monitoring.html
- Previous Article :Drinking water monitoring system
- Next Article:Hospital water quality monitoring
Related article
-
Campus Weather Station: Bridging Education, Research and Community Services
2025-02-27 -
Agricultural meteorological stations
2024-09-03 -
Lightweight & Stable: The Remote Controlled Lifebuoy Advantage
2025-09-16 -
Soil Moisture Monitor for Scientific Moisture Management
2025-09-19 -
No Solar Dependence & Easy Deployment: What Makes Water Level Gauge Ideal for Urban Waterlogging Monitoring
2025-09-02 -
Soil Moisture Temperature Salinity PH Tester FT-WSYP1: Supporting Precision Agriculture and Research
2025-07-31 -
What are crop growth monitoring instruments?
2024-04-30 -
Soil Moisture Monitor: Guiding Farmers to Master Wheat Field Moisture Management
2024-12-02


Get a Free Quote