Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- Water Level Measurement Achieving High-Precision, Stable Water Level Output in Deep Wells
- How Soil Moisture Monitoring Systems Enable Unattended Field Monitoring
- Groundwater level monitoring Achieving High-Precision, Stable Water Level Measurement in Deep Wells
- How Agricultural Weather Stations Achieve High-Precision, Low-Power Monitoring in the Field
- How Manufacturers of Water Conservancy Monitoring Equipment Address Data Transmission in Areas Without Signal Coverage
- How Soil Moisture Monitors Enable Simultaneous Measurement Across Six Soil Layers
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Weighing Lysimeter
Model:FT-ZS30
Brand:fengtu
Related products
Product details
1、Weighing Lysimeter Product Overview
Weighing Lysimeter enables field-based study of soil evaporation and water balance by precisely calculating evapotranspiration and percolation rates in agricultural land through the monitoring of changes in soil mass (via weighing).Soil evaporation is a critical component of the soil water cycle. Weighing Lysimeter serves as an essential, convenient, and flexible tool for studying soil moisture evaporation. It can be used to measure soil evaporation in areas with growing crops, on bare soil, or beneath a crop canopy, delivering highly accurate results. The core component features a high-precision load cell, ensuring enhanced stability. With an RS485 output, the device can be integrated into existing data loggers or observation systems, enabling automated weighing, measurement, and data storage—thereby reducing research costs.
2、Weighing Lysimeter System Components
1 micro-lysimeter, 1 data logger, 1 solar power supply system, 1 equipment enclosure, and 1 mounting assembly (a 2-meter, two-section galvanized steel mast with a diameter of at least 76 mm, including a base or expansion bolt hardware).
3、Weighing Lysimeter Product Features
High precision; designed for in-ground installation to minimize disturbance; enables convenient and rapid extraction of undisturbed soil samples.
4、Weighing Lysimeter Technical Specifications
Soil column specifications: 30 cm in diameter, cylindrical container, made of stainless steel.
Evaporation resolution: ≤0.1 mm;
Percolation (leaching) resolution: ≤0.03 mm;
Integrated external protective structure, featuring a stainless steel rain-shield enclosure;
Automatic drainage system, with accumulated water pumped out automatically.
2. Data Acquisition and Transmission Unit
The main environmental data logger displays collected environmental data in real time. Core: ARM architecture.
Display screen for showing data, time, date, parameter settings, etc.
Equipped with a watchdog circuit and automatic reset function to ensure stable system operation.
Supports expandable USB flash drive storage, allowing data to be exported to a computer via dedicated host-side software.
Reporting modes: Supports both active (push) and passive (polled/request-based) reporting, switchable on the device. Protocols (XPH, MODBUS, JSON) and the device’s serial communication address can be configured manually.
Supports remote or local firmware upgrades via serial port.
Allows for parameter configuration via physical buttons on the device.
Historical data storage interval can be manually set between 1 and 240 minutes.
Equipped with wireless communication hardware, supporting remote configuration updates.
1) Includes 3 years of communication service fees.
2) Supports 4G, Wi-Fi, and GPS.
3) Provides stable relay communication services with reliable and consistent performance.
4) All data links must be located within China; the use of overseas data links or foreign servers for data transmission or relay is strictly prohibited.
5) Communication relay servers must not store, back up, forward, or share data with third parties.
3. Technical Specifications
Electrical safety performance complies with the GB4793.1-2007 standard; the insulation resistance between the power terminals and the IoT terminal enclosure must be at least 10 MΩ. When powered by an AC source, the device must withstand a 3000V high-voltage test for 1 minute without breakdown or arcing.
Under normal operating conditions, the leakage current must not exceed 5 mA (AC).
Environmental adaptability complies with GB/T2423.1-2008, GB/T2423.2-2008, and GB/T2423.3-2016 standards. Operating temperature range: -40°C to 85°C; operating humidity range: 0–95% RH (non-condensing).
This paper addresses:https://www.fengtusz.com/Lysimeter/Weighing-Lysimeter.html
- Previous Article :no more
- Next Article:Soil Lysimeter
Related article
-
Components of a water quality testing system
2024-05-15 -
Water Quality Monitoring: Dissolved Oxygen and the Role of FT - SS04 Portable Water Quality Meter
2025-02-12 -
Water Level Monitoring Station: A Key to Hydrological Insights
2024-09-25 -
FT - LS1: Precision in Soil Erosion Monitoring
2025-01-17 -
High Altitude Insect Detection Lamp, Environmental Protection Insect Killing Lamps
2024-03-29 -
The Significance and Function of Handheld Weather meter in the Wild
2025-03-17 -
Radar water level monitoring stations utilize non-contact radar technology to achieve millimeter-level precise water level measurement
2026-06-30 -
Fengtu FT - ZS1S COD Analyzer: Scalable & Accurate Water Monitor
2025-03-06


Get a Free Quote






