Product Center
-
Hydrological equipment monitoring station
-
Water Quality Monitor Sensor
-
Plant protection equipment
-
Food Testing Equipment
- The standard buoy five-parameter monitoring system enables automatic water quality data acquisition and remote transmission
- How the Tubular Soil Temperature and Moisture Monitor Achieves Simultaneous Multi-Layer Soil Parameter Measurement
- IoT Water Quality Monitoring Station enables the automatic acquisition and remote transmission of in-situ water quality monitoring data
- Soil Moisture Monitoring Enables Simultaneous Measurement of Soil Temperature and Moisture at Multiple Depths
- The high-spec buoy with five parameters enables more accurate lake water quality monitoring
- Advantages and Application Scenarios of Non-Contact Measurement Technology for Radar Water Level Monitoring Equipment
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Tel, Whatsapp:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Total Phosphorus Analyzer
Model:FT-SZZL
Brand:fengtu
Related products
Product details
1.Total Phosphorus Analyzer Principle
Total Phosphorus Analyzer is suitable for monitoring the total phosphorus content in surface water, municipal sewage and industrial wastewater.Under high temperature and high pressure conditions, the sample is digested with potassium persulfate, and all phosphorus compounds in the sample are converted to orthophosphate (this step is not required for measuring orthophosphate). In a 5%-8% nitric acid solution, orthophosphate forms a soluble phosphorus-vanadium-molybdenum yellow complex with ammonium metavanadate and ammonium molybdate, and its absorbance is measured at a specific wavelength. The absorbance is linearly related to the orthophosphate concentration of the sample. Based on this relationship, the absorbance can be converted into the total phosphorus (TP) or orthophosphate (PO4) concentration value of the sample.
2. Product Features of Total Phosphorus Analyzer
The new photoelectric quantitative technology is not affected by interference such as large chromaticity, large amounts of suspended matter, and large amounts of bubbles. It has high reliability and accuracy and strong anti-interference ability.
High detection accuracy, low measurement limit and small long-term drift of the instrument.
It has one-button self-test function and self-diagnosis function.
Adopt single-channel highly integrated valve group, maintenance and cleaning are simple and quick.
All-weather networking function, monitor the instrument operation status anytime and anywhere.
It has alarm function, quality control function and reverse control function.
It has automatic cleaning and automatic calibration functions.
It has functions of hourly measurement, interval measurement and external control measurement.
It will work automatically after power failure.
Automatic prompt and automatic reset function for fault and reagent (sample) shortage.
With fault recording function.
Can save historical data for more than 3 years.
Meet the requirement of separate discharge of cleaning liquid and waste liquid
3. Total Phosphorus Analyzer Technical Parameters
Measurement method: Ammonium molybdate spectrophotometry (HJ670-2013)
Measuring range: 0-2 mg/L; 0-10 mg/L; 0-50 mg/L; range can be customized
Indication error: ≤±3% Detection limit: 0.010mg/L
Repeatability: ≤±3% Waste volume: 4.5mL/time
Memory effect: ≤±1% Actual water sample comparison: ±8%
Constant temperature time: 900 seconds Voltage stability: ≤±5%
Measurement cycle: 39 minutes Calibration cycle: any specified time
Maintenance cycle: ≥720h/time Maintenance workload: <2 hours/month
Reagent consumption: 3 months/500ml Display output: Equipped with 10.1-inch color LCD touch screen
Color development temperature: recommended temperature is 120℃, can be set according to the actual water sample conditions
Data export: The measured values can be imported into a USB flash drive and saved via the USB port
Signal output: RS485/RS232/USB interface/standard 2-way 4-20mA output/standard 2-way switch input and output
Environmental requirements: Temperature-controlled indoor environment, recommended temperature (5-28°C), humidity ≤ 90% (no condensation)
Power supply and power: (220V±22)V/AC, (50±0.5Hz), 5A, 150W
Instrument size: upper cabinet 600*450*300mm; upper cabinet 700*450*300mm
This paper addresses:https://www.fengtusz.com/water-quality-monitoring-station/Total-Phosphorus-Analyzer.html
- Previous Article :Online Ammonia Nitrogen analyzer
- Next Article:Total Nitrogen Analyzer
Related article
-
Water Level Monitoring Station: Enabling Efficient Water Resource Management
2024-12-25 -
Rice Planthopper Monitor: Ensuring Efficient Pest Control and Monitoring
2024-10-23 -
What is an integrated weather station?
2024-04-24 -
Agro-meteorological observation instruments, agricultural auxiliary research tools
2024-04-09 -
Soil Moisture Sensor: Precise Installation for Reliable Soil Moisture Monitoring
2024-11-20 -
Soil Moisture Monitor: Guiding Farmers to Master Wheat Field Moisture Management
2024-12-02 -
Campus Weather Station: Bridging Education, Research and Community Services
2025-02-27 -
Micro Water Quality Monitor: Meeting the Urgent Need for Dense Water Quality Monitoring
2024-09-30


Get a Free Quote